AguaClara Flow Control and Measurement Technologies
This section explores AguaClara’s search for constant head in chemical dosing. The term constant head means that the driving head of a system, \(\Delta z\) or \(\Delta h\), does not change over time, even as water flows through or out of the system. Constant head implies constant flow, since the energy driving the flow does not change.
The challenge of constant head in chemical dosing for water treatment plants is not just providing one continuous flow of chemicals; it is also varying that flow of chemicals as the flow rate through the plant changes, so that the concentration of chemicals in the raw water stays the same.
Before diving into the technologies, recall the purpose of the chemicals that we are seeking to constantly dose, and why it is important to keep a constant, specific dose. Also recall that ‘dose’ means ‘concentration of chemical’ in the water we are trying to treat, not in the stock tanks of the chemicals. Coagulant like alum, PAC, and some iron-based chemicals are used to turn small particles into bigger particles, allowing them to be captured more easily. Waters with high turbidity, indicative of a lot of particles like clay and bacteria, require more coagulant to treat effectively. Additionally, waters with a lot of organic matter require significantly more coagulant to treat. Chlorine is used to disinfect water that has already been fully treated. A proper and consistent chlorine dose is required, as too low of a dose creates a risk of reintroduction of pathogens in the distribution system and too high of a dose increases the risk of carcinogenic disinfection byproduct formation.
Important
This section will often refer to the proportionality between flow \(Q\) and head \(\Delta h\) (recall that \(\Delta h = h_L\) after applying the head loss trick) by using the ‘proportional to’ symbol, \(\propto\). It is important to remember that it doesn’t necessarily matter whether \(Q\) or \(h_L\) goes first, \(Q \propto \sqrt{h_L}\) is equivalent to saying that \(h_L \propto Q^2\).
“Almost Linear” Flow Controller
This device consists of a bottle of chemical solution, called the Constant Head Tank (CHT), a float valve to keep a solution in the CHT at a constant water level, a flexible tube starting at the bottom of the CHT, and many precisely placed and equally spaced holes in a pipes. The holes in the pipe hold the other end of the tube that starts at the CHT. Chemical solution, either coagulant or chlorine, is stored in a stock tank somewhere above the CHT. A different tube connects the stock tank to the float valve within the CHT.
This flow controller provides a constant flow of chemical solution to the water in the plant. When the end of the flexible tube is placed in a hole, the elevation difference between the water level in the bottle and the hole is set and does not change unless the tube is then placed in another hole. Thus, a constant flow is provided while the end of the tube is not moved.
As has been mentioned previously, the amount of chlorine and coagulant that must be added to the raw water changes depending on the flow rate of the plant; the change is necessary to keep the dose constant. More water flowing through the plant means more chlorine is necessary to maintain the dose of chlorine in the treated water. For coagulant, there are also other factors aside from plant flow rate that impact the required dose, including the turbidity and amount of organic matter in the water. The operator must be able to change the dose of both coagulant and chlorine quickly and easily, and they must be able to know the value of the new dose they set. The “Almost Linear” Flow Controller accomplishes this by having a large number of holes in the flow control pipe next to the CHT. This large number of holes gives the operator many options for adjusting the dose, and let them quickly change the flow of chemicals into the raw water by moving the end of the flexible tube from one hole to another.
The idea behind this flow controller is to have a linear relationship between \(Q\) and \(h_L\) (remember that \(h_L\) is equal to \(\Delta h\) when we apply the head loss trick), which can be written as \(Q \propto h_L\). Here, \(Q\) is the flow of chemicals out of the flexible tube, and \(h_L\) is the elevation difference between the water level in the CHT and the end of the flexible tube.
As you remember from section 1.5, the summary of Fluids Review, \(Q \propto \Delta h\), or \(\Delta h \propto Q\) as it was written in the section summary, is only true for the combination of major losses and laminar flow, which makes applicable the Hagen-Poiseuille equation. Therefore, the flow must always be laminar in the flexible tube that goes between the CHT and the holes, and major losses must far exceed minor losses.
It is easy to design for laminar flow, but the “Almost Linear” Flow Controller was unable to make major losses far exceed minor losses. The bending in the flexible tube caused a lot of minor losses which changed in magnitude depending on exactly how the tube was bent. This made the flow controller “almost linear,” but that wasn’t good enough.
Notes:
This flow controller is no longer used by AguaClara.
The tube connecting the CHT to the outlet of chemicals must be very long and, more importantly, straight to form a linear relationship between driving head and flow. This linear relationship was not true for the “Almost Linear” Flow Controller, and is why it was replaced by the Linear Chemical Dose Controller (CDC). The CDC will be covered in more depth later on in this section.
Linear Flow Orifice Meter (LFOM)
The LFOM is a weir shape cut into a pipe. It was meant to imitate the Sutro Weir while being far easier to build. The LFOM is a pipe with rows of holes, or orifices, drilled into it. There are progressively fewer holes per row as you move up the LFOM, as the shape is meant to resemble half a parabola on each side. The size of all holes is the same, and the amount of holes per row are precisely calculated. Water in the entrance tank flows into and down the LFOM, towards the rapid mix orifice and flocculator.
The LFOM does one thing and serves two purposes.
What it does:
The LFOM creates a linear relationship between water level in the entrance tank and the flow out of the entrance tank. It does not control the flow through the plant. If the LFOM were replaced with a hole in the bottom of the entrance tank, the same flow rate would go through the plant, the only difference being that the water level in the entrance tank would scale with flow squared \(h \propto Q^2\) instead of \(h \propto Q\). For example, if an LFOM has 10 rows of holes and has been designed for a plant whose maximum flow rate is 10 L/s, then the operator knows that the number of rows submerged in water is equal to the flow rate of the plant in L/s. So if the water were up to the third row of holes, there would be 3 L/s of water flowing through the plant.
Why it is useful:
Allows the operator to measure the flow through the plant quickly and easily, explained above.
Allows for the Linear Chemical Dose Controller, which will be explained next, to automatically adjust the flow of coagulant/chlorine into the plant as the plant flow rate changes. This means the operator would only need to adjust the flow of coagulant when there is a change in turbidity or organic matter.
This is best understood with examples. By shaping a weir differently, different relationships between \(Q\) and \(h\) are formed: * In the case of a rectangular weir, \(Q \propto h^{\frac{3}{2}}\) * In the case of a v-notch weir, \(Q \propto h^{\frac{5}{2}}\) * In the case of a Sutro weir and thus LFOM, \(Q \propto h\).
Before the water level reaches the second row of holes, the LFOM is simulating a rectangular weir, and thus \(h \not\propto Q\). The Sutro weir also experiences this problem. Similarly, if the water level exceeds the topmost row of the LFOM’s orifices, the linearity also breaks down. The entire LFOM begins to act like an orifice, the exponent of \(Q\) in \(h \propto Q\) becomes greater than 1. This is because the LFOM approaches orifice behavior, and for orifices, \(h \propto Q^2\).
The diameter of the LFOM pipe is set by the velocity of the falling water inside the LFOM at the bottom of the bottom row of orifices. This velocity is obtained by summing up all of the momentum of the falling water and dividing by the total flow for the case where the LFOM is operating at maximum capacity. The Sutro weir equations (not yet provided here) can be integrated to obtain an equation for the falling velocity of the water inside the LFOM. This maximum vertical velocity of the falling water sets the minimum flow area of the LFOM and hence continuity can be used to obtain the minimum pipe diameter.
Linear Chemical Dose Controller (CDC)
Since the Linear Chemical Dose Controller has become the AguaClara standard chemical dosing system, it is often simply called the Chemical Dose Controller, or CDC for short (see Fig. 60).
The CDC brings together the LFOM and many improvements to the “Almost Linear” Flow Controller. Let’s break it down, with the image below as a guide.
Start at the Constant Head Tank (CHT). This is the same set up as the “Almost Linear” Flow Controller. The stock tank feeds into the CHT, and the float valve makes sure that the water level in the constant head tank is always the same.
Now the tubes. These fix the linearity problems that were the main problem in the “Almost Linear” Flow Controller.
The tube connected to the bottom of the CHT is large diameter to minimize any head loss through it.
The three thin, straight tubes are designed to generate a lot of major losses and to minimize any minor losses. This is to make sure that major losses far exceed any minor losses, which will ensure that the Hagen-Poiseuille equation is applicable and that flow will be directly proportional to the head, \(Q \propto \Delta h\). Why are there 3 tubes?
3 short instead of 1 short Removing 2 of the 3 tubes would mean 3 times the flow through the remaining tube. This means the velocity in the tube would be 3 times as fast. Since minor losses scale with \(v^2\) and major losses only scale with \(v\), this would increase the ratio of \(\rm{\frac{minor \, losses}{major \, losses}}\), which would break the linearity we’re trying to achieve. It would also increase the total head loss through the system, resulting in a lower maximum flow rate than before.
1 long instead of 3 short One tube whose length is equal to the three combined would be inconveniently long, and would suffer from the same problems as above. There would be even more head loss through the tube, since its length would be longer.
The large-diameter tube on the right of the three thin, straight tubes is where the chemicals flow out. The end of the tube is connected to both a slider and a ‘drop tube.’ The drop tube allows for supercritical flow of the chemical leaving the dosing tubes; once the chemical enters the drop tube it falls freely and no longer affects the CDC system.
The slider rests on a lever. This lever is the critical part of the CDC, it connects the water level in the entrance tank, which is adjusted by the LFOM, to the difference in head between the CHT and the end of the dosing tube. This allows the flow of chemicals to automatically adjust to a change in the plant flow rate, maintaining a constant dose in the plant water. One end of the lever tracks the water level in the entrance tank by using a float. The counterweight on the other side of the lever is to make sure the float ‘floats,’ since this float is usually made of PVC, which is more dense than water.
The slider itself controls the dose of chemicals. For any given plant flow rate, the slider can be adjusted to increase or decrease the amount of chemical flowing through the plant.
The CDC makes it easy and accurate to dose chemicals. The flow of chemicals automatically adjusts to changes in the plant flow rate to keep a constant dose, set by the operator. When a turbidity event occurs, the operator can change the dose of coagulant by moving the coagulant slider lower on the lever to increase the dose. The slider has labelled marks so the operator can record the dose accurately.
A lot of design has gone into the CDC. The design equations and their derivations that the following steps are based on can be found here: Design Equations for the Linear Chemical Dose Controller (CDC), and you are very, very strongly encouraged to read them.
The CDC can be designed manually using the equations from the derivation linked above or via aguaclara, using the equations found in cdc_functions.py. Either way, the design algorithm is roughly the same:
Calculate the maximum flow rate, \(Q_{max, \, Tube}\), through each available dosing tube diameter \(D\) that keeps error due to minor losses below 10% of total head loss. Recall that tubing diameter is an array, as there are many diameters available at hardware stores and suppliers. This means that for each step, there will be as many solutions as there are reasonable diameters available.
Calculate how much flow of chemical needs to pass through the CDC at maximum plant flow and maximum chemical dose. This depends on the concentration of chemicals in the stock tank.
Calculate the number of dosing tubes required if the tubes flow at maximum capacity (round up)
Calculate the length of dosing tube(s) that correspond to each available tube diameter.
Select a tube length from your array of solutions. Pick the longest dosing tube that you can, keeping in mind that the tube(s) must be able to fit in the plant and can’t be longer than the length of the plant wall it will be placed along.
Finally, select the dosing tube diameter and flow rate corresponding to the selected tube length.
Chemical Feed Stock Concentrations
The AguaClara plants in Honduras have used chlorine stock concentrations between 9 and 11 g/L of calcium hypochlorite. The stainless steel cotter pin in the float valve only lasts about 4 months when the stock concentration is 11 g/L. Thus a maximum calcium hypochlorite concentration of 9 g/L is recommended. A supply of stainless steel cotter pins should be maintained at each plant or a chlorine and acid resistant replacement should be developed. Given the low cost of the stainless steel cotter pins it is likely most cost effective to simply put those pins on a regular replacement schedule. A PVC pin could be used, but PVC is weak in comparison with stainless steel. A larger pin diameter would be needed and could be used by enlarging the hole in the valve. Unfortunately there isn’t much material available in the float valve to allow a significant increase in pin diameter.
The maximum coagulant stock concentrations had been 120 g/L as granular PACl prior to the plant at Gracias, Honduras. At Gracias the coagulant stock concentration was 150 g/L of granular PACl. As the concentration of PACl increases it becomes more difficult to mix, the viscosity of the solution increases, and the rate of incrustation of the float valve and dosing tubes increases.
At Gracias with 11 g/L of calcium hypochlorite and 150 g/L of granular PACl the operators need to disassemble and clean the dosing systems for both chlorine and PACl once per week. At other AguaClara plants the maintenance interval varies between 2 and 4 weeks. Maintenance for the chlorine system includes removal of the float valve and the dosing tubes and then cleaning those with vinegar to dissolve the deposition of calcium carbonate. The scaling that forms from polyaluminum chloride is water soluble and can be removed with water.
The dosing systems should either be designed to be cleaned with vinegar in place or to be easily disassembled and cleaned. Given the relatively large volume of 1/2” diameter PVC piping that connects the components of the system the preferred option thus far has been to remove the dosing tubes and the float valves for cleaning. We have used barbed fittings for the dosing tubes, but it is quite challenging to remove tubing from barbed fittings and the result has been premature failure of those fittings. For future chemical dosing systems our goal is to use an easy to disconnect coupling that doesn’t require taking the tubing off of the barbed fittings for cleaning.
Main Tube diameter
The flexible tubing that transports a chemical feed from the dosing tubes to the chemical dose controller and for the coagulant, from the chemical dose controller to the injection port, must be large enough in diameter so that the head loss is very small compared with the head loss of the LFOM. Both major and minor losses may be significant for these chemical pipes because the tubes are relatively long (high L/d ratio) and entrance, exit, and geometry changes in fittings will contribute to minor losses. The tubing diameter can be selected based on the chemical that requires the largest tubing diameter to reduce the number of different types of fitting and tubing required by the water treatment plant.
Summary
LFOM: The LFOM makes the water level in the entrance tank linear with respect to the flow out of the entrance tank. This is useful in measuring the flow and is a critical component in AguaClara’s chemical dosing system. The LFOM measures the flow through the plant, it does not control the flow through the plant.
The Linear Chemical Dose Controller (CDC) combines the: * linear relationship between water level and flow in the entrance tank caused by the LFOM, * linear relationship between elevation difference and flow caused by the Hagen-Poiseuille equation, which is only valid for major losses under laminar flow, and * a lever to link the two linear relationships
To keep the chemical dose constant by automatically adjusting the addition of coagulant and chlorine as the plant flow rate varies. Two sliders on the lever allows the operator to change the dose of coagulant and chlorine independently of the plant flow rate.